ANALOG AUDIO 12 PAIR, 26AWG/0.14mm², LSZH
Product Overview
| Suitable Applications | Audio snake cable used in professional studios; For the transmission of analogue signals |
|---|
Physical Characteristics (Overall)
CONDUCTOR
| AWG | Stranding | Material | Cross Section | Construction n x D |
|---|---|---|---|---|
| 26 | 7×34 | BC-OFHC – Oxygen-Free Bare Copper (High Conductivity) | 0.14 mm² | 7×0.16 mm |
| Conductor Count | 24 |
|---|---|
| Total Number of Pairs | 12 |
INSULATION
| Type | Material | Nominal Diameter | Diameter +/- Tolerance |
|---|---|---|---|
| Insulation | PE – Polyethylene | 1.00 mm | 0.03 mm |
COLOR CHART
| Number | Color |
|---|---|
| Pair 1 t/m 12 | White & Red |
INNER SHIELD
| Type | Material | Material Trade Name | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | Beldfoil® | 100% | Stranded tinned copper | 26 | 7×0.16 mm |
| Table Notes | Aluminum inside |
|---|
INNER JACKET
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 2.80 mm | 0.10 mm |
| Table Notes | Elements are numbered for identification |
|---|
OUTER SHIELD
| Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG | Drainwire Construction n x D |
|---|---|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | TC – Tinned Copper | 26 | 7×0.16 mm |
OUTER JACKET
| Material | Nominal Diameter | Nominal Wall Thickness |
|---|---|---|
| LSZH – Low Smoke Zero Halogen (Flame Retardant) | 14.00 mm | 1.30 mm |
Construction and Dimensions
CABLING
| Description | Filler |
|---|---|
| 3 fillers + 12 pairs | Cotton (3x) |
Electrical Characteristics
CONDUCTOR DCR
| Nominal Conductor DCR |
|---|
| 134.0 Ohm/km |
CAPACITANCE
| Nom. Capacitance Conductor to Conductor |
|---|
| 90 pF/m |
DELAY
| Nominal Velocity of Propagation (VP) [%] |
|---|
| 66% |
Temperature Range
| Other Temp Range | -30 to +70 °C |
|---|
Mechanical Characteristics
| Min. Bend Radius During Installation | 140 mm |
|---|---|
| Min Setting Radius | 70 mm |
Applicable Environmental and Other Programs
| Environmental Space | Indoor |
|---|
Flammability, LS0H, Toxicity Testing
| IEC Flammability | IEC 60332-1-2 |
|---|---|
| LOI of Jacket | Min. 34 % |
| IEC 60754-1 – Halogen Amount | Zero |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity | 2.5 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH | 4.3 |



Reviews
There are no reviews yet.